docling/tests/data/xml/pubmed-PMC13900.nxml

2 lines
51 KiB
Plaintext

<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Archiving and Interchange DTD v2.3 20070202//EN" "archivearticle.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article"><?properties open_access?><front><journal-meta><journal-id journal-id-type="nlm-ta">Breast Cancer Res</journal-id><journal-title>Breast Cancer Research</journal-title><issn pub-type="ppub">1465-5411</issn><issn pub-type="epub">1465-542X</issn><publisher><publisher-name>BioMed Central</publisher-name><publisher-loc>London</publisher-loc></publisher></journal-meta><article-meta><article-id pub-id-type="pmid">11250746</article-id><article-id pub-id-type="pmc">13900</article-id><article-id pub-id-type="publisher-id">BCR-3-1-055</article-id><article-categories><subj-group subj-group-type="heading"><subject>Primary Research</subject></subj-group></article-categories><title-group><article-title>Comparison of written reports of mammography, sonography and magnetic resonance mammography for preoperative evaluation of breast lesions, with special emphasis on magnetic resonance mammography</article-title></title-group><contrib-group><contrib id="A1" contrib-type="author"><name><surname>Malur</surname><given-names>Sabine</given-names></name><xref ref-type="aff" rid="I1">1</xref></contrib><contrib id="A2" contrib-type="author"><name><surname>Wurdinger</surname><given-names>Susanne</given-names></name><xref ref-type="aff" rid="I2">2</xref></contrib><contrib id="A3" contrib-type="author"><name><surname>Moritz</surname><given-names>Andreas</given-names></name><xref ref-type="aff" rid="I1">1</xref></contrib><contrib id="A4" contrib-type="author"><name><surname>Michels</surname><given-names>Wolfgang</given-names></name><xref ref-type="aff" rid="I1">1</xref></contrib><contrib id="A5" contrib-type="author"><name><surname>Schneider</surname><given-names>Achim</given-names></name><xref ref-type="aff" rid="I1">1</xref><email>aschneider@med.uni-jena.de</email></contrib></contrib-group><aff id="I1"><label>1</label>Department of Gynecology, Friedrich-Schiller University, Jena, Germany.</aff><aff id="I2"><label>2</label>Institute for Diagnostic and Interventional Radiology, Friedrich-Schiller University, Jena, Germany.</aff><pub-date pub-type="ppub"><year>2001</year></pub-date><pub-date pub-type="epub"><day>2</day><month>11</month><year>2000</year></pub-date><volume>3</volume><issue>1</issue><fpage>55</fpage><lpage>60</lpage><history><date date-type="received"><day>12</day><month>4</month><year>2000</year></date><date date-type="rev-request"><day>22</day><month>5</month><year>2000</year></date><date date-type="rev-recd"><day>24</day><month>6</month><year>2000</year></date><date date-type="accepted"><day>5</day><month>10</month><year>2000</year></date></history><copyright-statement>Copyright &#x000a9; 2000 BioMed Central Ltd on behalf of the copyright holders</copyright-statement><abstract><p>Patients with abnormal breast findings (<italic>n</italic> = 413) were examined by mammography, sonography and magnetic resonance (MR) mammography; 185 invasive cancers, 38 carcinoma <italic>in situ</italic> and 254 benign tumours were confirmed histologically. Sensitivity for mammography was 83.7%, for sonography it was 89.1% and for MR mammography it was 94.6% for invasive cancers. In 42 patients with multifocal invasive cancers, multifocality had been detected by mammography and sonography in 26.2%, and by MR mammography in 66.7%. In nine patients with multicentric cancers, detection rates were 55.5, 55.5 and 88.8%, respectively. Carcinoma <italic>in situ</italic> was diagnosed by mammography in 78.9% and by MR mammography in 68.4% of patients. Combination of all three diagnostic methods lead to the best results for detection of invasive cancer and multifocal disease. However, sensitivity of mammography and sonography combined was identical to that of MR mammography (ie 94.6%).</p></abstract><kwd-group><kwd>breast lesions</kwd><kwd>diagnostic methods</kwd></kwd-group></article-meta></front><body><sec><title>Introduction</title><p>Mammography and sonography are the standard imaging techniques for detection and evaluation of breast disease [<xref ref-type="bibr" rid="B1">1</xref>]. Mammography is the most established screening modality [<xref ref-type="bibr" rid="B2">2</xref>]. Especially in young women and women with dense breasts, sonography appears superior to mammography, and differentiation between solid tumours and cysts is easier. Sensitivity and specificity of sonography or mammography are higher if sonography and mammography are combined [<xref ref-type="bibr" rid="B3">3</xref>].</p><p>It is generally accepted that MR mammography is the most sensitive technique for diagnosis of breast cancer, whereas the reported specificity of MR mammography varies [<xref ref-type="bibr" rid="B4">4</xref>,<xref ref-type="bibr" rid="B5">5</xref>,<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B7">7</xref>,<xref ref-type="bibr" rid="B8">8</xref>,<xref ref-type="bibr" rid="B9">9</xref>,<xref ref-type="bibr" rid="B10">10</xref>,<xref ref-type="bibr" rid="B11">11</xref>,<xref ref-type="bibr" rid="B12">12</xref>]. In those studies, MR mammography was performed and evaluated by highly specialized radiologists in a research setting. It was therefore the purpose of the present prospective study to compare the validity of MR mammography with mammography and sonography in clinical routine practice. Findings for the three diagnostic methods documented on routine reports that were available to the surgeon preoperatively formed the basis of this comparison. Special emphasis was placed on the identification of multifocal and multicentric invasive disease.</p></sec><sec sec-type="methods"><title>Patients and methods</title><sec><title>Patients</title><p>Between September 1995 and September 1998, 413 patients with abnormal breast findings were referred for histological evaluation to the Department of Gynecology of the Friedrich-Schiller University, Jena, Germany. Patients had been selected and referred because of the presence of breast lesions detected by palpation and/or mammography and/or sonography. In addition, MR mammography was performed in all patients. We excluded five patients with invasive cancer who had a history of core-needle or fine-needle biopsy cancer within 2 weeks before referral, because the presence of haematoma may mimic false-positive findings on MR mammography. In addition, five patients who did not keep still during MR mammography were excluded.</p></sec><sec><title>Imaging</title><p>Analysis of the sonograms taken in patients with histologically confirmed carcinoma <italic>in situ</italic> were excluded from analysis because the value of sonography for detection of premalignant disease is limited. Mammography was not performed in 32 patients who were younger than 30 years or who had had a mastectomy with suspected local recurrence. For all patients, written reports of mammographic, sonographic and dynamic MR mammographic findings were available preoperatively.</p><p>The majority of mammograms (68%) were performed at the Institute for Diagnostic and Interventional Radiology, Friedrich-Schiller-University, using a senograph DMR (GE Medical Systems, Milwaukee, Wisconsin, USA) with standard craniocaudal and mediolateral oblique projections. Mammograms obtained at other institutions that were considered to match the quality standards of our institution were also accepted for evaluation.</p><p>All sonography and MR examinations were carried out at the Department of Gynecology and the Institute for Diagnostic Interventional Radiology, Friedrich-Schiller-University, respectively. Sonography was done using a 7.5-MHz linear array probe with a Sonoline Versa Pro (Siemens, Erlangen, Germany). MR mammography was performed exclusively at the Institute for Diagnostic Interventional Radiology, using a Gyroscan ACSII (Philips, Nijmegen, The Netherlands) with a field strength of 1.5 T using a double-breast coil. Dynamic T1-weighted images were aquired using a multislice two-dimensional fast-field-echo (FFE) sequence. We used the following parameters: TR 97, TE 5.0, flip angle 80&#x000b0;, slice thickness 4.0 mm, gap 0.4 mm, field of view 350 mm and transverse orientation. In addition T2-weighted images (4000/300/90&#x000b0;/4.0 mm/0.4/350 mm) were obtained. As contrast medium, 0.1 mmol gadolinium-DTPA/kg body weight (Magnevist; Schering, Berlin, Germany) was used and injected as a bolus. One unenhanced and seven enhanced studies were acquired with an acquisition time of 1 min. Criteria for malignancy were signal enhancement of 90% or more within the first 2 min after bolus injection and signal plateau or washout phenomena afterward. Additional criteria were irregular borders of the lesion and low signal intensity in the T2-weighted images.</p><p>Mammograms were read by three different radiologists, sonography was done by three different gynaecologists and MR mammography was interpreted by a total of six different radiologists.</p><p>Definition for multifocal carcinoma was a distance of less than 3 cm and for multicentric carcinoma a distance over 3 cm between various lesions.</p></sec><sec><title>Statistical analysis</title><p>Interpretation of the various diagnostic procedures was compared with the histological examination with regard to sensitivity, specificity, accuracy, and positive and negative predictive value. Criteria for suspected malignancy in the written reports were the terms 'cancer', 'malignant lesion or tumor', or 'suspicious for cancer'. Sensitivity, specificity, negative and positive predicitive value, and accuracy were evaluated as follows:</p><p>Sensitivity = patients with suspected breast cancer/patients with histologically confirmed breast cancer</p><p>Specificity = patients with suspected benign disease/patients with histologically confirmed benign disease</p><p>Positive predictive value = patients with histologically confirmed breast cancer/patients with suspected breast cancer</p><p>Negative predictive value = patients with histologically confirmed benign disease/patients with suspected benign disease</p><p>Accuracy = patients with true-positive and true-negative detected disease/patients with histologically confirmed breast cancer</p><p>A result was classified as false-negative when a diagnostic method classified a histologically confirmed cancer as benign. A result was classified as false-positive when a diagnostic method classified a histologically confirmed benign lesion as cancer. We compared the preformance of all diagnostic methods individually and in combination using the results from all patients. Statistical analysis was performed for all variables with Fisher's exact test and Pearson's &#x003c7;<sup>2</sup> test.</p></sec></sec><sec><title>Results</title><p>All patients underwent breast surgery and all abnormal lesions identified by mammography, sonography or MR mammography were surgically removed. A total of 477 breast lesions were examined histologically, revealing the presence of 185 invasive cancers, 38 carcinomata <italic>in situ</italic> and 254 benign lesions (fibroadenoma, papilloma, intraductal or adenoid ductal hyperplasia, cystic mastopathia). There were four patients with malignant lesions in both breasts. In 42 patients multifocal tumours and in nine patients multicentric tumors were found on histological examination. Among the 185 invasive lesions, 178 were primary cancers, five were recurrences, one was metastatic and one was an angiosarcoma. The majority of invasive breast cancers were staged as pT1c (44%). Six per cent of tumors were detected in stage pT1a, 18% in stage pT1b, 25% in stage pT2, 3% in stage pT3 and 4% in stage pT4. The distribution of histopathological tumour types is shown in Table <xref ref-type="table" rid="T1">1</xref>. The mean age of patients was 58 years (range 19-85 years).</p><p>The sensitivity of MR mammography was significantly higher than those of mammography and sonography (<italic>P</italic> &#x0003c; 0.005 and <italic>P</italic> &#x0003c; 0.05; Table <xref ref-type="table" rid="T2">2</xref>). The specificity of sonography was significantly higher than those of mammography and MR mammography (<italic>P</italic> &#x0003c; 0.05 and <italic>P</italic> &#x0003c; 0.005; Table <xref ref-type="table" rid="T2">2</xref>). The negative predictive values for sonography and MR mammography were significantly higher than that of mammography (<italic>P</italic> &#x0003c; 0.05 and <italic>P</italic> &#x0003c; 0.005; Table <xref ref-type="table" rid="T2">2</xref>). With regard to accuracy, no significant difference between the three modalities was found (Table <xref ref-type="table" rid="T2">2</xref>). Combining of all three diagnostic methods yielded the best results for detection of cancer (<italic>P</italic> &#x0003c; 0.005; Table <xref ref-type="table" rid="T3">3</xref>). The sensitivity and negative predictive value for the combination of mammography and MR mammography, and the combination of sonography and MR mammography were significantly higher than those for the combination of mammograpy and sonography (<italic>P</italic> &#x0003c; 0.05; Table <xref ref-type="table" rid="T3">3</xref>). The highest result for accuracy was seen for a combination of all three methods (<italic>P</italic> &#x0003c; 0.05; Table <xref ref-type="table" rid="T3">3</xref>).</p><p>Mammography was false-negative in 30 out of 184 invasive cancers, sonography was false-negative in 20 out of 185 cancers, and 10 out of 185 invasive cancers were missed by MR mammography. The majority of false-negative findings was found in stage1 disease, ductal carcinoma and grade 3 tumors (Table <xref ref-type="table" rid="T4">4</xref>). Of 10 invasive cancers missed by MR mammography, eight were found by mammography and sonography. By all three techniques, one invasive ductal carcinoma (pT1b) was misinterpreted as fibroadenoma. In another patient, a microinvasive lobular carcinoma of 5 mm diameter was not detected with mammography and MR mammography, whereas sonography detected a solid, benign tumour. MR mammography identified 10 invasive cancers (5.2%) that were missed by mammography and sonography, whereas one invasive cancer was found by mammography alone. By sonography alone, not a single case of invasive disease was detected when MR mammography or mammography were nonsuspected.</p><p>The highest detection rate for multifocal invasive disease was seen with MR mammography, which identified 28 out of 42 (66.7%) histologically confirmed multifocal invasive cancers, whereas mammography and sonography both identified 11 (26.2%) of these cancers (<italic>P</italic> &#x0003c; 0.05). The combination of all three diagnostic methods leads to the best result for detection of multifocality (76.2%; <italic>P</italic> &#x0003c; 0.05), whereas the detection rate with the combination of mammography and sonography was 35.7%, with the combination of sonography and MR mammography it was 69% (<italic>P</italic> &#x0003c; 0.05 versus mammography + sonography), and with the combination of mammography and MR mammography it was 73.8% (<italic>P</italic> &#x0003c; 0.05 versus mammography + sonography). Multifocal invasive disease was suspected in 12 patients by mammography, in 13 patients by sonography, and in 16 patients by MR mammography, but only unifocal disease was confirmed by histology. Out of nine patients with histologically confirmed multicentric invasive cancer, eight (88.8%) of these cancers were detected by MR mammography and five (55.5%) by mammography or sonography. One patient was diagnosed with multicentric invasive-lobular carcinoma stage pT2G2, which had been misinterpreted as benign tumour by sonography and mammography, and as haematoma by MR mammography.</p><p>Out of 38 patients with carcinoma <italic>in situ</italic>, mammography (suspicious microcalcifications, exclusively) identified 30 cases (78.9%) and MR mammography identified 26 cases (68.4%). When combining mammography and MR mammography, sensitivity for detection of carcinoma <italic>in situ</italic> increased to 87% (not significant).</p></sec><sec><title>Discussion</title><p>When the validity of individual diagnostic methods for detection of invasive breast cancer was analyzed, the sensitivity and specificity of mammography ranged from 79.9 to 89% and from 64 to 93.5%, respectively [<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B7">7</xref>,<xref ref-type="bibr" rid="B13">13</xref>]; for sonography from 67.6 to 96% and from 93 to 97.7%, respectively [<xref ref-type="bibr" rid="B13">13</xref>,<xref ref-type="bibr" rid="B14">14</xref>]; and for MR mammography from 91 to 98.9 and from 20 to 97.4%, respectively [<xref ref-type="bibr" rid="B6">6</xref>,<xref ref-type="bibr" rid="B7">7</xref>,<xref ref-type="bibr" rid="B8">8</xref>,<xref ref-type="bibr" rid="B9">9</xref>,<xref ref-type="bibr" rid="B10">10</xref>,<xref ref-type="bibr" rid="B15">15</xref>,<xref ref-type="bibr" rid="B16">16</xref>,<xref ref-type="bibr" rid="B17">17</xref>].</p><p>The performance of mammography, sonography and MR mammography was compared in three large series (Table <xref ref-type="table" rid="T5">5</xref>). The present results are similar with regard to sensitivity and specificity for the detection of malignant breast lesions, with MR mammography reaching the highest sensitivity of all imaging procedures.</p><p>When combinations of all three technique were analyzed, mammography and sonography (standard method) had a sensitivity of 83% and a specificity of 92% for detection of malignant disease [<xref ref-type="bibr" rid="B3">3</xref>]. A combination of mammography, sonography and MR mammography (combined method) showed a sensitivity of 95% and a specificity of 64% [<xref ref-type="bibr" rid="B3">3</xref>]. For nonpalpable lesions, sensitivity increased from 73% by the standard method to 82% for the combined method. Specificity for the standard method (89%) was higher than that for the combined method (71%). For palpable lesions a sensitivity of 85% for the standard and 98% for the combined method was achieved, whereas specificity for the standard method was 100% compared with 45% for the combined methods [<xref ref-type="bibr" rid="B3">3</xref>]. The positive predictive value was 94% for the standard and 80% for the combined methods, and the negative predictive values were 78 and 89%, respectively [<xref ref-type="bibr" rid="B3">3</xref>]. In the present study, we also found the highest sensitivity, specificity, and positive and negative predictive values for the combination of all three methods. Combination of mammography and sonography was as sensitive as MR mammography alone (94.6% versus 94.6%).</p><p>The majority of false-positive results for invasive cancer by MR mammography (80 out of 439) were caused by papillomas, intraductal hyperplasia grade 2 or 3, or fibroadenomas in the present series. These lesions have a good blood supply and may mimic invasive cancer [<xref ref-type="bibr" rid="B16">16</xref>,<xref ref-type="bibr" rid="B18">18</xref>].</p><p>Ten out of 185 (5.4%) malignant lesions were classified as false-negative by MR mammography. On histology, the majority of false-negative invasive cancers were lobular cancers (four out of 10). Bone <italic>et al</italic> [<xref ref-type="bibr" rid="B18">18</xref>] reported false-negative results in 11 out of 155 readings, with the majority being lobular cancers on histology. Lack of tumour-induced neovascularity may explain such findings. In particular, invasive lobular cancers infiltrate the normal tissue with columns of single cells, and receive adequate oxygenation without the requirement for increased vascularization [<xref ref-type="bibr" rid="B19">19</xref>]. Buadu <italic>et al</italic> [<xref ref-type="bibr" rid="B11">11</xref>] found that lobular and mucinous carcinomas had a low microvessel density.</p><p>Multifocality of breast cancers can be recognized adequately by MR mammography [<xref ref-type="bibr" rid="B20">20</xref>,<xref ref-type="bibr" rid="B21">21</xref>]. Boetes <italic>et al</italic> [<xref ref-type="bibr" rid="B22">22</xref>] reported that all 61 multifocal cancers were detected by MR mammography, compared with 31% by mammography and 38% by sonography. Esserman <italic>et al</italic> [<xref ref-type="bibr" rid="B20">20</xref>] detected multifocality by MR mammography in 100% (10 out of 10) versus 44% (four out of nine) by mammography. Relevant changes in therapy due to additional multicentric and contralateral tumour findings by MR mammography occur in 18% of patients as compared with conventional imaging [<xref ref-type="bibr" rid="B23">23</xref>]. We found a detection rate of multifocality of 66.7% by MR mammography, as compared with 26.2% by mammography and sonography. However, in 16 patients multifocal invasive disease as diagnosed by MR mammography was shown to be unifocal by histology.</p><p>Kramer <italic>et al</italic> [<xref ref-type="bibr" rid="B24">24</xref>] reported that MR mammography yielded the highest sensitivity for detection of multicentricity as compared with mammography and sonography (89, 66 and 79%, respectively) in 38 patients. These findings are comparable with the present results, in which eight out of nine multicentric cancers were diagnosed correctly.</p><p>Carcinoma <italic>in situ</italic> is identified by mammography through the presence of suspicious microcalcifications. Suspicious microcalcifications are more frequent in intraductal than in infiltrating cancers [<xref ref-type="bibr" rid="B25">25</xref>], which was also observed in the present series. Mammography showed a detection rate for carcinoma <italic>in situ</italic> of 78.9%, as compared with 65.8% by MR mammography; the combination of mammography and MR mammography lead to a detection rate of 86.4%. Fischer <italic>et al</italic> [<xref ref-type="bibr" rid="B26">26</xref>] reported that carcinoma <italic>in situ</italic> was identified by MR mammography in 25 out of 35 patients (72%); three ductal carcinomata <italic>in situ</italic> were detected by MR mammography exclusively. Sittek <italic>et al</italic> [<xref ref-type="bibr" rid="B27">27</xref>] reported that 14 out of 20 carcinomata <italic>in situ</italic> (70%) were correctly diagnosed by MR mammography on the basis of focal increase of signal intensity. Those authors concluded that carcinoma <italic>in situ</italic> is not reliably detected by MR mammography because of lack of a uniform pattern of enhancement. Esserman <italic>et al</italic> [<xref ref-type="bibr" rid="B20">20</xref>] reported a detection rate of 43% for ductal carcinoma <italic>in situ</italic> by MR mammography. Among 36 woman with carcinoma <italic>in situ</italic>, Gilles <italic>et al</italic> [<xref ref-type="bibr" rid="B28">28</xref>] demonstrated two cases without early contrast enhancement.</p><p>The present study showed that, for detection of breast cancer, MR mammography is not superior to a combination of sonography and mammography. For identification of multifocal or multicentric disease, MR mammography proved to be the most accurate technique.</p></sec></body><back><ref-list><ref id="B1"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Orel</surname><given-names>SG</given-names></name><name><surname>Troupin</surname><given-names>RH</given-names></name></person-group><article-title>Nonmammographic imaging of the breast: current issues and future prospects.</article-title><source>Semin Roentgenol</source><year>1993</year><volume>28</volume><fpage>231</fpage><lpage>241</lpage><pub-id pub-id-type="pmid">8211231</pub-id></citation></ref><ref id="B2"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kerlikowske</surname><given-names>K</given-names></name><name><surname>Grady</surname><given-names>D</given-names></name><name><surname>Rubin</surname><given-names>SM</given-names></name><name><surname>Sandrock</surname><given-names>C</given-names></name><name><surname>Ernster</surname><given-names>VL</given-names></name></person-group><article-title>Efficancy of screening mammography.</article-title><source>JAMA</source><year>1995</year><volume>273</volume><fpage>149</fpage><lpage>154</lpage><pub-id pub-id-type="pmid">7799496</pub-id></citation></ref><ref id="B3"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>M&#x000fc;ller-Schimpfle</surname><given-names>M</given-names></name><name><surname>Stoll</surname><given-names>P</given-names></name><name><surname>Stern</surname><given-names>W</given-names></name><name><surname>Kutz</surname><given-names>S</given-names></name><name><surname>Dammann</surname><given-names>F</given-names></name><name><surname>Claussen</surname><given-names>CD</given-names></name></person-group><article-title>Do mammography, sonography and MR mammography have a diagnostic benefit compared with mammography and sonography?</article-title><source>AJR Am J Roentgenol</source><year>1997</year><volume>168</volume><fpage>1323</fpage><lpage>1329</lpage><pub-id pub-id-type="pmid">9129436</pub-id></citation></ref><ref id="B4"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Heywang</surname><given-names>SH</given-names></name><name><surname>Hahn</surname><given-names>D</given-names></name><name><surname>Schmidt</surname><given-names>H</given-names></name><name><surname>Krischke</surname><given-names>I</given-names></name><name><surname>Eiermann</surname><given-names>W</given-names></name><name><surname>Bassermann</surname><given-names>R</given-names></name><name><surname>Lissner</surname><given-names>J</given-names></name></person-group><article-title>MR imaging of the breast using gadolinium-DTPA.</article-title><source>J Comput Assist Tomogr</source><year>1986</year><volume>10</volume><fpage>199</fpage><lpage>204</lpage><pub-id pub-id-type="pmid">3950145</pub-id></citation></ref><ref id="B5"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kaiser</surname><given-names>WA</given-names></name><name><surname>Zeitler</surname><given-names>E</given-names></name></person-group><article-title>MR mammography: first clinical results [in German].</article-title><source>R&#x000f6;ntgenpraxis</source><year>1985</year><volume>38</volume><fpage>256</fpage><lpage>262</lpage></citation></ref><ref id="B6"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kacl</surname><given-names>GM</given-names></name><name><surname>Liu</surname><given-names>P</given-names></name><name><surname>Debatin</surname><given-names>JF</given-names></name><name><surname>Garzoli</surname><given-names>E</given-names></name><name><surname>Caduff</surname><given-names>RF</given-names></name><name><surname>Krestin</surname><given-names>GP</given-names></name></person-group><article-title>Detection of breast cancer with conventional mammography and contrast-enhanced MR imaging.</article-title><source>Eur Radiol</source><year>1998</year><volume>8</volume><fpage>194</fpage><lpage>200</lpage><pub-id pub-id-type="pmid">9477265</pub-id></citation></ref><ref id="B7"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bone</surname><given-names>B</given-names></name><name><surname>Pentek</surname><given-names>Z</given-names></name><name><surname>Perbeck</surname><given-names>L</given-names></name><name><surname>Veress</surname><given-names>B</given-names></name></person-group><article-title>Diagnostic accuracy of mammography and contrast-enhanced MR imaging in 238 histologically verified breast lesions.</article-title><source>Acta Radiol</source><year>1997</year><volume>38</volume><fpage>489</fpage><lpage>496</lpage><pub-id pub-id-type="pmid">9240665</pub-id></citation></ref><ref id="B8"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kaiser</surname><given-names>WA</given-names></name></person-group><article-title>MR Mammographie.</article-title><source>Radiologe</source><year>1993</year><volume>33</volume><fpage>292</fpage><lpage>299</lpage><pub-id pub-id-type="pmid">8390704</pub-id></citation></ref><ref id="B9"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Heywang-K&#x000f6;brunner</surname><given-names>SH</given-names></name></person-group><article-title>Contrast-enhanced magnetic resonance imaging of the breast.</article-title><source>Invest Radiol</source><year>1994</year><volume>29</volume><fpage>94</fpage><lpage>104</lpage><pub-id pub-id-type="pmid">8144345</pub-id></citation></ref><ref id="B10"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Harms</surname><given-names>SE</given-names></name><name><surname>Flaming</surname><given-names>DP</given-names></name></person-group><article-title>MR imaging of the breast.</article-title><source>J Magn Reson Imaging</source><year>1993</year><volume>3</volume><fpage>277</fpage><lpage>283</lpage><pub-id pub-id-type="pmid">8428095</pub-id></citation></ref><ref id="B11"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Buadu</surname><given-names>LD</given-names></name><name><surname>Murakami</surname><given-names>J</given-names></name><name><surname>Murayama</surname><given-names>S</given-names></name><name><surname>Hashiguchi</surname><given-names>N</given-names></name><name><surname>Sakai</surname><given-names>S</given-names></name><name><surname>Masuda</surname><given-names>K</given-names></name><name><surname>Toyoshima</surname><given-names>S</given-names></name></person-group><article-title>Breast lesions: correlation of contrast medium enhancement patterns on MR images with histopathologic findings and tumor angiogenesis.</article-title><source>Radiology</source><year>1996</year><volume>200</volume><fpage>639</fpage><lpage>649</lpage><pub-id pub-id-type="pmid">8756909</pub-id></citation></ref><ref id="B12"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Orel</surname><given-names>SG</given-names></name><name><surname>Schnall</surname><given-names>MD</given-names></name><name><surname>LiVolsi</surname><given-names>VA</given-names></name><name><surname>Troupin</surname><given-names>RH</given-names></name></person-group><article-title>Suspicious breast lesions: MR imaging with radiologic-pathologic correlation.</article-title><source>Radiology</source><year>1994</year><volume>190</volume><fpage>485</fpage><lpage>493</lpage><pub-id pub-id-type="pmid">8284404</pub-id></citation></ref><ref id="B13"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ciatto</surname><given-names>S</given-names></name><name><surname>Rosselli del Turco</surname><given-names>M</given-names></name><name><surname>Catarzi</surname><given-names>S</given-names></name><name><surname>Morrone</surname><given-names>D</given-names></name></person-group><article-title>The contribution of sonography to the differential diagnosis of breast cancer.</article-title><source>Neoplasma</source><year>1994</year><volume>41</volume><fpage>341</fpage><lpage>345</lpage><pub-id pub-id-type="pmid">7870218</pub-id></citation></ref><ref id="B14"><citation citation-type="other"><person-group person-group-type="author"><name><surname>Oh</surname><given-names>KK</given-names></name><name><surname>Cho</surname><given-names>JH</given-names></name><name><surname>Yoon</surname><given-names>CS</given-names></name><name><surname>Jung</surname><given-names>WH</given-names></name><name><surname>Lee</surname><given-names>HD</given-names></name></person-group><article-title>Comparative studies of breast diseases by mammography, ultrasonography and contrast-enhanced dynamic magnetic resonance imaging.</article-title><source>Breast Ultrasound Update. Edited by Madjar H, Teubner J, Hackel&#x000f6;er BJ. Basel: Karger;</source><year>1994</year><fpage>332</fpage><lpage>343</lpage></citation></ref><ref id="B15"><citation citation-type="other"><person-group person-group-type="author"><name><surname>Heywang</surname><given-names>SH</given-names></name></person-group><article-title>MRI in breast disease.</article-title><source>Book of Abstracts: Society of Magnetic Resonance in Medicine 1. Berkeley, CA.</source><year>1993</year><fpage>abstract 113</fpage></citation></ref><ref id="B16"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kaiser</surname><given-names>WA</given-names></name></person-group><article-title>False-positive results in dynamic MR mammography. Causes, frequency and methods to avoid.</article-title><source>Magn Reson Imaging Clin North Am</source><year>1994</year><volume>2</volume><fpage>539</fpage><lpage>555</lpage></citation></ref><ref id="B17"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Heywang-Koebrunner</surname><given-names>SH</given-names></name><name><surname>Vieweg</surname><given-names>P</given-names></name><name><surname>Heinig</surname><given-names>A</given-names></name><name><surname>Kuchler</surname><given-names>C</given-names></name></person-group><article-title>Contrast-enhanced MRI of the breast: accuracy, value, controversies, solutions.</article-title><source>Eur J Radiol</source><year>1997</year><volume>24</volume><fpage>94</fpage><lpage>108</lpage><pub-id pub-id-type="pmid">9097051</pub-id></citation></ref><ref id="B18"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bone</surname><given-names>B</given-names></name><name><surname>Aspelin</surname><given-names>P</given-names></name><name><surname>Bronge</surname><given-names>L</given-names></name><name><surname>Isberg</surname><given-names>B</given-names></name><name><surname>Perbeck</surname><given-names>L</given-names></name><name><surname>Veress</surname><given-names>B</given-names></name></person-group><article-title>Sensitivity and specificity of MR mammography with histopathological correlation in 250 breasts.</article-title><source>Acta Radiol</source><year>1996</year><volume>37</volume><fpage>208</fpage><lpage>213</lpage><pub-id pub-id-type="pmid">8600964</pub-id></citation></ref><ref id="B19"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Stelling</surname><given-names>CB</given-names></name></person-group><article-title>MR imaging of the breast for cancer evaluation: current status and future directions.</article-title><source>Radiol Clin North Am</source><year>1995</year><volume>33</volume><fpage>1187</fpage><lpage>1204</lpage><pub-id pub-id-type="pmid">7480665</pub-id></citation></ref><ref id="B20"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Esserman</surname><given-names>L</given-names></name><name><surname>Hylton</surname><given-names>N</given-names></name><name><surname>Yassa</surname><given-names>L</given-names></name><name><surname>Barclay</surname><given-names>J</given-names></name><name><surname>Frankel</surname><given-names>S</given-names></name><name><surname>Sickles</surname><given-names>E</given-names></name></person-group><article-title>Utility of magnetic resonance imaging in the managment of breast cancer: evidence for improved preoperative staging.</article-title><source>J Clin Oncol</source><year>1999</year><volume>17</volume><fpage>110</fpage><lpage>119</lpage><pub-id pub-id-type="pmid">10458224</pub-id></citation></ref><ref id="B21"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kaiser</surname><given-names>WA</given-names></name><name><surname>Diedrich</surname><given-names>K</given-names></name><name><surname>Reiser</surname><given-names>M</given-names></name><name><surname>Krebs</surname><given-names>D</given-names></name></person-group><article-title>Modern diagnostics of the breast [in German].</article-title><source>Geburtsh u Frauenheilk</source><year>1993</year><volume>53</volume><fpage>1</fpage><lpage>14</lpage></citation></ref><ref id="B22"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Boetes</surname><given-names>C</given-names></name><name><surname>Mus</surname><given-names>R</given-names></name><name><surname>Holland</surname><given-names>R</given-names></name><name><surname>Barentsz</surname><given-names>JO</given-names></name><name><surname>Strijk</surname><given-names>SP</given-names></name><name><surname>Wobbes</surname><given-names>T</given-names></name><name><surname>Hendriks</surname><given-names>JH</given-names></name><name><surname>Ruys</surname><given-names>SH</given-names></name></person-group><article-title>Breast tumors: comparative accuracy of MR imaging relative to mammography and US for demonstration extent.</article-title><source>Radiology</source><year>1995</year><volume>197</volume><fpage>743</fpage><lpage>747</lpage><pub-id pub-id-type="pmid">7480749</pub-id></citation></ref><ref id="B23"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fischer</surname><given-names>U</given-names></name><name><surname>Vossheinrich</surname><given-names>R</given-names></name><name><surname>Kopka</surname><given-names>L</given-names></name><name><surname>von Heyden</surname><given-names>D</given-names></name><name><surname>Oestmann</surname><given-names>JW</given-names></name><name><surname>Grabbe</surname><given-names>EH</given-names></name></person-group><article-title>Preoperative MR mammography in patients with breast cancer: impact of therapy [abstract].</article-title><source>Radiology</source><year>1994</year><volume>193</volume><fpage>121</fpage><pub-id pub-id-type="pmid">8090879</pub-id></citation></ref><ref id="B24"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kramer</surname><given-names>S</given-names></name><name><surname>Schultz-Wendtland</surname><given-names>R</given-names></name><name><surname>Hagedorn</surname><given-names>K</given-names></name><name><surname>Bautz</surname><given-names>W</given-names></name><name><surname>Lang</surname><given-names>N</given-names></name></person-group><article-title>Magnetic resonace imaging and its role in the diagnosis of multicentric breast cancer.</article-title><source>Anticancer Res</source><year>1998</year><volume>18</volume><fpage>2163</fpage><lpage>2164</lpage><pub-id pub-id-type="pmid">9703777</pub-id></citation></ref><ref id="B25"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ciatto</surname><given-names>S</given-names></name><name><surname>Rosselli del Turco</surname><given-names>M</given-names></name><name><surname>Bonardi</surname><given-names>R</given-names></name><name><surname>Cataliotta</surname><given-names>L</given-names></name><name><surname>Distante</surname><given-names>V</given-names></name><name><surname>Cardona</surname><given-names>G</given-names></name><name><surname>Bianchi</surname><given-names>S</given-names></name></person-group><article-title>Non-palpable lesions of the breast detected by mammography: review of 1182 consecutive histologically confirmed cases.</article-title><source>Eur J Cancer</source><year>1994</year><volume>30A</volume><fpage>40</fpage><lpage>44</lpage><pub-id pub-id-type="pmid">8142162</pub-id></citation></ref><ref id="B26"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fischer</surname><given-names>U</given-names></name><name><surname>Westerhof</surname><given-names>JP</given-names></name><name><surname>Brinck</surname><given-names>U</given-names></name><name><surname>Korabiowska</surname><given-names>M</given-names></name><name><surname>Schauer</surname><given-names>A</given-names></name><name><surname>Grabbe</surname><given-names>E</given-names></name></person-group><article-title>Ductal carcinoma <italic>in situ</italic> in dynamic MR mammography at 1.5 T [in German].</article-title><source>Fortschr R&#x000f6;ntgenstr</source><year>1996</year><volume>164</volume><fpage>290</fpage><lpage>294</lpage></citation></ref><ref id="B27"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sittek</surname><given-names>H</given-names></name><name><surname>Kessler</surname><given-names>M</given-names></name><name><surname>Heuck</surname><given-names>AF</given-names></name><name><surname>Bredl</surname><given-names>T</given-names></name><name><surname>Perlet</surname><given-names>C</given-names></name><name><surname>K&#x000fc;nzer</surname><given-names>I</given-names></name><name><surname>Lebeau</surname><given-names>A</given-names></name><name><surname>Untch</surname><given-names>M</given-names></name><name><surname>Reiser</surname><given-names>M</given-names></name></person-group><article-title>Morphology and contrast enhancement of ductal carcinoma <italic>in situ</italic> in dynamic 1.0 T MR mammography [in German].</article-title><source>Fortschr R&#x000f6;ntgenstr</source><year>1997</year><volume>167</volume><fpage>2247</fpage><lpage>2251</lpage></citation></ref><ref id="B28"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gilles</surname><given-names>R</given-names></name><name><surname>Zafrani</surname><given-names>B</given-names></name><name><surname>Guinebretiere</surname><given-names>JM</given-names></name><name><surname>Meunier</surname><given-names>M</given-names></name><name><surname>Lucidarme</surname><given-names>O</given-names></name><name><surname>Tardivon</surname><given-names>AA</given-names></name><name><surname>Rochard</surname><given-names>F</given-names></name><name><surname>Vanel</surname><given-names>D</given-names></name><name><surname>Neuenschwander</surname><given-names>S</given-names></name><name><surname>Arriagada</surname><given-names>R</given-names></name></person-group><article-title>Ductal carcinoma in situ: MR imaging-histopathologic correlation.</article-title><source>Radiology</source><year>1995</year><volume>196</volume><fpage>415</fpage><lpage>419</lpage><pub-id pub-id-type="pmid">7617854</pub-id></citation></ref><ref id="B29"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Buchberger</surname><given-names>W</given-names></name><name><surname>Kapferer</surname><given-names>M</given-names></name><name><surname>St&#x000f6;ger</surname><given-names>A</given-names></name><name><surname>Chemelli</surname><given-names>A</given-names></name><name><surname>Judmaier</surname><given-names>W</given-names></name><name><surname>Felber</surname><given-names>S</given-names></name></person-group><article-title>Dignity evaluation of focal mamma lesions: a prospective comparison between mammography, sonography and dynamic MR mammography [in German; abstract].</article-title><source>Radiologe</source><year>1995</year><volume>35</volume><fpage>86</fpage></citation></ref><ref id="B30"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Heywang</surname><given-names>SH</given-names></name><name><surname>Wolf</surname><given-names>A</given-names></name><name><surname>Pruss</surname><given-names>E</given-names></name><name><surname>Hilbertz</surname><given-names>T</given-names></name><name><surname>Eiermann</surname><given-names>W</given-names></name><name><surname>Permanetter</surname><given-names>W</given-names></name></person-group><article-title>MR imaging of the breast with Gd-DTPA: use and limitations.</article-title><source>Radiology</source><year>1989</year><volume>171</volume><fpage>95</fpage><lpage>103</lpage><pub-id pub-id-type="pmid">2648479</pub-id></citation></ref></ref-list><sec sec-type="display-objects"><title>Figures and Tables</title><table-wrap position="float" id="T1"><label>Table 1</label><caption><p>Histopathology of 185 invasive cancers</p></caption><table frame="hsides" rules="groups"><thead><tr><td align="left">Histopathologic diagnosis</td><td align="center">Number of lesions</td></tr></thead><tbody><tr><td align="left">Ductal carcinoma</td><td align="center">109</td></tr><tr><td align="left">Lobular carcinoma</td><td align="center">36</td></tr><tr><td align="left">Mixed ductal/lobular carcinoma</td><td align="center">16</td></tr><tr><td align="left">Mucinous carcinoma</td><td align="center">2</td></tr><tr><td align="left">Medullary carcinoma</td><td align="center">3</td></tr><tr><td align="left">Tubular carcinoma</td><td align="center">13</td></tr><tr><td align="left">Others (metaplastic carcinoma,</td><td align="center">6</td></tr><tr><td align="left">&#x02003;angiosarcoma, metastases)</td><td></td></tr></tbody></table></table-wrap><table-wrap position="float" id="T2"><label>Table 2</label><caption><p>Comparison of mammography, sonography and MR mammography for preoperative prediction of histologically confirmed invasive cancer (<italic>n</italic> = 185) or benign disease (<italic>n</italic> = 254)</p></caption><table frame="hsides" rules="groups"><thead><tr><td align="left">Diagnostic method</td><td align="center">Sensitivity (%)</td><td align="center">Specificity (%)</td><td align="center">PPV (%)</td><td align="center">NPV (%)</td><td align="center">Accuracy (%)</td></tr></thead><tbody><tr><td align="left">Mammography</td><td align="center">83.7</td><td align="center">68.5</td><td align="center">67.8</td><td align="center">84.1</td><td align="center">77.1</td></tr><tr><td align="left">Sonography</td><td align="center">89.1</td><td align="center">79.1<sup>*&#x02020;</sup></td><td align="center">65.7</td><td align="center">90.9<sup>&#x02021;</sup></td><td align="center">83.4<sup>&#x02020;</sup></td></tr><tr><td align="left">MR mammography</td><td align="center">94.6<sup>*&#x02020;</sup></td><td align="center">68.5</td><td align="center">68.6</td><td align="center">94.6<sup>&#x02020;</sup></td><td align="center">79.5</td></tr></tbody></table><table-wrap-foot><p><sup>*</sup><italic>P</italic> &#x0003c; 0.005, versus MR mammography; <sup>&#x02020;</sup><italic>P</italic> &#x0003c; 0.05, versus mammography; <sup>&#x02021;</sup><italic>P</italic> &#x0003c; 0.05, versus sonography. NPV, negative predictive value; PPV, positive predictive value.</p></table-wrap-foot></table-wrap><table-wrap position="float" id="T3"><label>Table 3</label><caption><p>Comparison of various combinations of three diagnostic methods for preoperative prediction of histologically confirmed invasive cancer (<italic>n</italic> = 185) or benign disease (<italic>n</italic> = 254)</p></caption><table frame="hsides" rules="groups"><thead><tr><td align="left">Diagnostic methods</td><td align="center">Sensitivity (%)</td><td align="center">Specificity (%)</td><td align="center">PPV (%)</td><td align="center">NPV (%)</td><td align="center">Accuracy (%)</td></tr></thead><tbody><tr><td align="left">Mammography + MR mammography</td><td align="center">98.9<sup>*</sup></td><td align="center">90.5</td><td align="center">88.4</td><td align="center">99.1<sup>*</sup></td><td align="center">94.1</td></tr><tr><td align="left">Sonography + MR mammography</td><td align="center">98.9<sup>*</sup></td><td align="center">93.3</td><td align="center">91.5</td><td align="center">99.2<sup>*</sup></td><td align="center">95.7</td></tr><tr><td align="left">Mammography + sonography</td><td align="center">94.6</td><td align="center">92.1</td><td align="center">89.7</td><td align="center">95.9</td><td align="center">93.2</td></tr><tr><td align="left">All three methods combined</td><td align="center">99.4<sup>&#x02020;</sup></td><td align="center">95.3</td><td align="center">93.9</td><td align="center">99.6<sup>&#x02020;</sup></td><td align="center">97.0<sup>&#x02020;&#x02021;</sup></td></tr></tbody></table><table-wrap-foot><p><sup>*</sup><italic>P</italic> &#x0003c; 0.05, versus mammography and sonography; <sup>&#x02020;</sup><italic>P</italic> &#x0003c; 0.005, versus mammography and sonography; <sup>&#x02021;</sup><italic>P</italic> &#x0003c; 0.05, versus MR mammography and mammography. NPV, negative predictive value; PPV, positive predictive value.</p></table-wrap-foot></table-wrap><table-wrap position="float" id="T4"><label>Table 4</label><caption><p>Analysis of false-negative diagnosis of mammography (<italic>n</italic> = 30), sonography (<italic>n</italic> = 20) and MR mammography (<italic>n</italic> = 10) for 185 invasive cancers</p></caption><table frame="hsides" rules="groups"><thead><tr><td align="left">Cancer</td><td></td><td></td><td align="center">MR</td></tr><tr><td align="left">characteristics</td><td align="center">Mammography</td><td align="center">Sonography</td><td align="center">mammography</td></tr></thead><tbody><tr><td align="left">Tumour stage</td><td></td><td></td><td></td></tr><tr><td align="left">&#x02003;1a</td><td align="center">1</td><td align="center">4</td><td align="center">3</td></tr><tr><td align="left">&#x02003;1b</td><td align="center">8</td><td align="center">5</td><td align="center">2</td></tr><tr><td align="left">&#x02003;1c</td><td align="center">11</td><td align="center">6</td><td align="center">3</td></tr><tr><td align="left">&#x02003;2</td><td align="center">6</td><td align="center">2</td><td align="center">2</td></tr><tr><td align="left">&#x02003;3</td><td align="center">1</td><td align="center">1</td><td align="center">0</td></tr><tr><td align="left">&#x02003;4 (inflammatory)</td><td align="center">3</td><td align="center">2</td><td align="center">0</td></tr><tr><td align="left">Histological type</td><td></td><td></td><td></td></tr><tr><td align="left">&#x02003;Ductal</td><td align="center">15</td><td align="center">13</td><td align="center">2</td></tr><tr><td align="left">&#x02003;Lobular</td><td align="center">11</td><td align="center">3</td><td align="center">4</td></tr><tr><td align="left">&#x02003;Others</td><td align="center">4</td><td align="center">4</td><td align="center">4</td></tr><tr><td align="left">Grading</td><td></td><td></td><td></td></tr><tr><td align="left">&#x02003;1</td><td align="center">2</td><td align="center">3</td><td align="center">1</td></tr><tr><td align="left">&#x02003;2</td><td align="center">10</td><td align="center">6</td><td align="center">5</td></tr><tr><td align="left">&#x02003;3</td><td align="center">18</td><td align="center">11</td><td align="center">4</td></tr></tbody></table></table-wrap><table-wrap position="float" id="T5"><label>Table 5</label><caption><p>Review of the literature: case series that compared mammography, sonography and MR mammography in patients with benign tumours and invasive cancer</p></caption><table frame="hsides" rules="groups"><thead><tr><td></td><td></td><td align="center" colspan="2">Mammography</td><td align="center" colspan="2">Sonography</td><td align="center" colspan="2">MR mamography</td></tr><tr><td></td><td></td><td colspan="2"><hr></hr></td><td colspan="2"><hr></hr></td><td colspan="2"><hr></hr></td></tr><tr><td align="left">Reference</td><td align="center"><italic>n</italic></td><td align="center">Sens (%)</td><td align="center">Spec (%)</td><td align="center">Sens (%)</td><td align="center">Spec (%)</td><td align="center">Sens (%)</td><td align="center">Spec (%)</td></tr></thead><tbody><tr><td align="left">[<xref ref-type="bibr" rid="B29">29</xref>]</td><td align="center">60</td><td align="center">82</td><td align="center">96</td><td align="center">79</td><td align="center">50</td><td align="center">95</td><td align="center">64</td></tr><tr><td align="left">[<xref ref-type="bibr" rid="B14">14</xref>]</td><td align="center">150</td><td align="center">88</td><td align="center">88</td><td align="center">96</td><td align="center">93</td><td align="center">98</td><td align="center">99</td></tr><tr><td align="left">[<xref ref-type="bibr" rid="B30">30</xref>]</td><td align="center">98</td><td align="center">91</td><td align="center">-</td><td align="center">83</td><td align="center">-</td><td align="center">98</td><td align="center">-</td></tr></tbody></table><table-wrap-foot><p>-, not indicated; Sens, sensitivity; Spec, specificity.</p></table-wrap-foot></table-wrap></sec></back></article>